Moving ground target detection with seismic signal using smooth pseudo Wigner–Ville distribution M Kalra, S Kumar, B Das IEEE Transactions on Instrumentation and Measurement 69 (6), 3896-3906, 2019 | 51 | 2019 |
Dual plane in-line digital holographic microscopy B Das, CS Yelleswarapu Optics letters 35 (20), 3426-3428, 2010 | 51 | 2010 |
Seismic signal analysis using empirical wavelet transform for moving ground target detection and classification M Kalra, S Kumar, B Das IEEE sensors journal 20 (14), 7886-7895, 2020 | 50 | 2020 |
Label-free detection of Escherichia coli bacteria by cascaded chirped long period gratings immunosensor S Kaushik, U Tiwari, N Nilima, S Prashar, B Das, RK Sinha Review of Scientific Instruments 90 (2), 2019 | 40 | 2019 |
Quantitative phase-contrast imaging through a scattering media RK Singh, AM Sharma, B Das Optics letters 39 (17), 5054-5057, 2014 | 39 | 2014 |
Holographic imaging through a scattering layer using speckle interferometry AS Somkuwar, B Das, RV Vinu, YK Park, RK Singh JOSA A 34 (8), 1392-1399, 2017 | 38 | 2017 |
Fiber-MZI-based FBG sensor interrogation: comparative study with a CCD spectrometer B Das, V Chandra Applied Optics 55 (29), 8287-8292, 2016 | 36 | 2016 |
Phase modulated gray-scale data pages for digital holographic data storage B Das, J Joseph, K Singh Optics communications 282 (11), 2147-2154, 2009 | 33 | 2009 |
Quantitative phase microscopy using dual-plane in-line digital holography B Das, CS Yelleswarapu, D Rao Applied optics 51 (9), 1387-1395, 2012 | 31 | 2012 |
Elimination of Light Intensity Noise Using Dual-Channel Scheme for fiber MZI based FBG Sensor Interrogation B Das, V Chandra, U Tiwari IEEE Sensors Journal 16 (8), 2431-2436, 2016 | 29 | 2016 |
Interrogation techniques for π-phase-shifted fiber Bragg grating sensor: A review S Deepa, B Das Sensors and Actuators A: Physical 315, 112215, 2020 | 27 | 2020 |
Performance analysis of content-addressable search and bit-error rate characteristics of a defocused volume holographic data storage system B Das, J Joseph, K Singh Applied Optics 46 (22), 5461-5470, 2007 | 26 | 2007 |
Revisit to comparison of numerical reconstruction of digital holograms using angular spectrum method and Fresnel diffraction method G Dwivedi, SK Debnath, B Das, R Kumar Journal of Optics 49, 118-126, 2020 | 25 | 2020 |
Interferometric interrogation of π-phase shifted fiber Bragg grating sensors D Srivastava, U Tiwari, B Das Optics Communications 410, 88-93, 2018 | 25 | 2018 |
High efficiency panchromatic photopolymer recording material for holographic data storage systems V Pramitha, B Das, J Joseph, R Joseph, K Sreekumar, CS Kartha Optical Materials 52, 212-218, 2016 | 23 | 2016 |
Parallel-quadrature phase-shifting digital holographic microscopy using polarization beam splitter B Das, CS Yelleswarapu, D Rao Optics communications 285 (24), 4954-4960, 2012 | 23 | 2012 |
Material saturation in photopolymer holographic data recording and its effects on bit-error-rate and content-addressable search B Das, J Joseph, K Singh Optics communications 282 (2), 177-184, 2009 | 21 | 2009 |
Lensless complex amplitude image retrieval through a visually opaque scattering medium B Das, NS Bisht, RV Vinu, RK Singh Applied Optics 56 (16), 4591-4597, 2017 | 19 | 2017 |
Seismic intensity estimation using multilayer perceptron for onsite earthquake early warning S Sarkar, A Roy, S Kumar, B Das IEEE Sensors Journal 22 (3), 2553-2563, 2021 | 17 | 2021 |
Tuning the sensitivity of a fiber-optic plasmonic sensor: An interplay among gold thickness, tapering ratio and surface roughness A Chopra, GC Mohanta, B Das, R Bhatnagar, SS Pal IEEE Sensors Journal 21 (10), 12153-12161, 2021 | 17 | 2021 |